A Study of the GORE® TAG® Thoracic Branch Endoprosthesis for Treating Proximal Descending Thoracic Aortic Aneurysms

Overview

About this study

The purpose of this study is to assess the feasibility of the use of the GORE® TAG® Thoracic Branch Endoprosthesis to treat aneurysms involving the proximal Descending Thoracic Aorta (DTA).

Participation eligibility

Participant eligibility includes age, gender, type and stage of disease, and previous treatments or health concerns. Guidelines differ from study to study, and identify who can or cannot participate. There is no guarantee that every individual who qualifies and wants to participate in a trial will be enrolled. Contact the study team to discuss study eligibility and potential participation.

Inclusion Criteria

  • Presence of DTA aneurysm needing surgical repair which requires proximal graft placement in Zone 2
    • Fusiform (≥ 55 mm), or
    • Fusiform (>2 times native aortic diameter), or
    • Saccular (no diameter criteria)
  • Age ≥18 years at time of informed consent signature
  • Subject is capable of complying with protocol requirements, including follow-up
  • Informed Consent Form (ICF) is signed by Subject or legal representative
  • Must have appropriate proximal aortic landing zone, defined as
    • Must require coverage of the left subclavian artery origin for exclusion of the lesion
    • Aortic inner diameters between 16-48 mm
    • Landing zone, which must include the left subclavian artery ostium, cannot be aneurysmal, heavily calcified, or heavily thrombosed
    • Acceptable proximal landing zone outer curvature length for the required device
    • Landing zone must be native aorta
  • Must have appropriate distal aortic landing zone, defined as
    • Outer curvature length must be ≥2cm proximal to the celiac artery
    • Aortic inner diameters between 16-48mm (diameter should be between 16-42mm if using distal TAG® Device extension)
    • Landing zone cannot be aneurysmal, heavily calcified, or heavily thrombosed
    • Native aorta or previously implanted GORE® TAG® Device
  • Must have appropriate LSA landing zone, defined as
    • LSA length of ≥3 cm proximal to first major branch vessel if using Aortic Component with 8 mm portal diameter, or LSA length of ≥2.5 cm proximal to first major branch vessel if using Aortic Component with 12 mm portal diameter
    • LSA inner diameters of 6-15 mm if using Aortic Component with 8 mm portal diameter, or inner diameters of 11-18 mm if using Aortic Component with 12 mm portal diameter
    • Target branch vessel landing zone cannot be aneurysmal, heavily calcified, or heavily thrombosed

Exclusion Criteria

  • Concomitant aneurysm/disease of the ascending aorta, aortic arch, or abdominal aorta requiring repair
  • Previous endovascular repair of the ascending aorta
  • Previous endovascular repair of the DTA with a non-Gore device
  • Surgery within 30 days of treatment
  • Infected aorta
  • Dissection of the DTA
  • Intramural hematoma of the DTA without DTA aneurysm
  • Life expectancy <2 years
  • Myocardial infarction or stroke within 6 weeks prior to treatment
  • Patient has a systemic infection and may be at increased risk of endovascular graft infection
  • Pregnant female at time of informed consent signature
  • Degenerative connective tissue disease, e.g. Marfan's or Ehler-Danlos Syndrome
  • Participation in another drug or medical device study within one year of study enrollment
  • Known history of drug abuse within one year of treatment
  • Significant thrombus or atheroma in the aortic arch
  • Tortuous or stenotic iliac and/or femoral arteries preventing introducer sheath insertion and the inability to use a conduit for vascular access
  • Planned coverage of left carotid or celiac arteries
  • Patient has known sensitivities or allergies to the device materials
  • Patient has known hypersensitivity or contraindication to anticoagulants or contrast media, which is not amenable to pre-treatment
  • Previous instance of Heparin Induced Thrombocytopenia type 2 (HIT-2) or known hypersensitivity to heparin
  • Diameter taper outside of the device sizing range between proximal and distal landing zones of aorta and the inability to use additional devices of different diameters to compensate for the taper
  • Mycotic aneurysm
  • Persistent refractory shock (systolic blood pressure <90 mm Hg)
  • Patient has body habitus or other medical condition which prevents adequate visualization of the aorta
  • For Subjects enrolled in Stage 1
    • Aberrant right subclavian or left vertebral arteries
    • Occluded/stenosed/hypoplastic right vertebral artery
    • Presence of a patent left internal mammary artery (LIMA) graft
    • Bilateral carotid artery disease
    • Known incomplete Circle of Willis
    • Known left vertebral artery ending in posterior inferior cerebellar artery (PICA)

Participating Mayo Clinic locations

Study statuses change often. Please contact the study team for the most up-to-date information regarding possible participation.

Mayo Clinic Location Status

Rochester, Minn.

Mayo Clinic principal investigator

Randall DeMartino, M.D., M.S.

Closed for enrollment

More information

Publications

Publications are currently not available

Additional contact information

Non-cancer trials contact form

Phone: 800-664-4542 (toll-free)

International patient clinical studies questions