-
NeoMend ProGEL™ Pleural Air Leak Sealant Post-Approval Study
Rochester, MN
The purpose of this post approval study is to further characterize the safety profile of the ProGEL™ Pleural Air Leak Sealant in commercial use, with specific reference to long-term safety over 90 days of follow-up.
-
Evaluation of the Spiration Valve for Emphysema to Improve Lung Function
Jacksonville, FL
This is a multicenter, prospective, randomized, controlled study designed to evaluate improvement of lung function after treatment with the Spiration Valve System as compared to medical management in the control group. The control group will be evaluated in the same manner as the treatment group.
The Spiration Valve is a small, umbrella-shaped, one-way valve that is placed inside the airways of one lung. It is used to redirect air from the less healthy to the more healthy parts of the lung. This helps to reduce over-inflation and may improve overall lung function and quality of life for people living ...
-
A Study to Evaluate the Clinical Utility for the Ion™ Endoluminal System
Rochester, MN
The purpose of this study is to evaluate the clinical utility and early performance of the FDA cleared Ion™ Endoluminal System (“Ion”) for brochoscopically approaching and facilitating the sampling of peripheral pulmonary nodules, between 1-3cm in size, of unknown etiology.
-
A Study Identifying Predictive Biomarkers for the Progression of Invasive Squamous Cell Carcinoma
Rochester, MN
The study will utilize both retrospective and prospective data collection from patients that already had a bronchoscopy and lung resection or will have a bronchoscopy and lung resection for squamous cell carcinoma. The investigators plan to prospectively collect 5 bronchoscopic biopsies, 3ml blood and one tumor and adjacent normal samples from 200 qualified patients who meet the study criteria.
-
Feasibility of Performing Peripheral Pulmonary Lesion Biopsy Using Robotic Bronchoscopy-Guided Cryoprobe
Rochester, MN
The purpose of this randomized control study is to evaluate the feasibility of using a miniature (1.1 mm) cryoprobe to perform biopsy of peripheral pulmonary lesions using robotic bronchoscopy.
-
Clinical Evaluation of ASP Health's Automated ROSE System for Bronchoscopic Applications
Rochester, MN
The purpose of this study is to compare cytology slides (bronchoscopically derived fine needle aspiration samples of lymph nodes at the time of rapid intraprocedural on site evaluation) created with the ASP Health's specimen preparation system to slides made by existing conventional methods.
-
The EMPrint™ Ablate and RESect Study in Patients With Metastatic Lung Tumors
No Locations
Post market prospective, non-randomized, single-arm, multicenter study, designed to demonstrate dose response of an ablation system using a percutaneous approach in patients with primary, metastatic, or recurrent primary lung tumors.
-
Postprocedural CT Scan in Patients Undergoing Bronchoscopic Lung Volume Reduction with Endobronchial Valves to Determine Benefit or Adverse Effects
Rochester, MN
The purpose of this story is to identify key radiographic variables that are predictive of symptomatic improvement in those patients undergoing endobronchial valve placement.
Symptomatic management of emphysema continues to be a difficult task by medical therapy alone. Bronchoscopic lung volume reduction (BLVR), utilizing minimal invasive placement of endobronchial valves, has emerged as a new therapeutic option. Early trial data demonstrated statistically and clinically significant improvement in FEV1, 6 minutes walk (6MW) distance, and quality of life. However, following the procedure, there are currently no good early predictors of symptomatic benefit. Often, patients wait several months to ...
-
MARK 1A Series: Percutaneous Microwave Ablation for Patients With Lung Tumor(s)
No Locations
The purpose of this study is to evaluate if lung ablation improves clinical outcomes for patients deemed to be surgically high-risk.